COVID-19 Announcement to Customers
Now Hiring! Apply Today
financing about us contact chat now

Heating Cooling Services Northford CT

Keep Your Home Comfortable With Quality HVAC Services In Northford CT

X-Treme Temp Heating & Cooling is your go-to HVAC service provider in Northford, CT! We’re the experts in home comfort year-round, from AC and heating repair to ductwork and water heaters. We’ve got you covered from installation to maintenance so you can have peace of mind about your heating and air conditioning.

Read the reviews below from Northford, CT residents to see what your neighbors say about our expertise and customer service. We can’t wait to work with you!

Local Reviews
for Northford, CT

X-Treme Temp Heating & Cooling, LLC Rated 5.0 out of 5 stars based on 8 customer reviews


Map of Northford, CT 06472

Exell




Review of X-Treme Temp Heating & Cooling, LLC

NorthfordCT06472 41.39-72.805

Map of Northford, CT 06472

A/C tuneup




Review of X-Treme Temp Heating & Cooling, LLC

Andrew does excellent job . Very friendly and explains what he is doing.

NorthfordCT06472 41.4175-72.735

Response from X-Treme Temp Heating & Cooling, LLC:

We're so happy to hear that our heating and cooling service exceeded your expectations. Thanks for leaving a positive review.


Map of Northford, CT 06472

Service done right!




Review of X-Treme Temp Heating & Cooling, LLC

Polite and swiftly completed the task

NorthfordCT06472 41.4025-72.79

Map of Northford, CT 06472

Great




Review of X-Treme Temp Heating & Cooling, LLC

Great

NorthfordCT06472 41.39-72.805

Map of Northford, CT 06472

Excellent service!




Review of X-Treme Temp Heating & Cooling, LLC

Larry was very professional, showed up within the time frame stated and took the time to explain everything.

NorthfordCT06472 41.405-72.7825

Map of Northford, CT 06472

Good service and communication




Review of X-Treme Temp Heating & Cooling, LLC

NorthfordCT06472 41.4175-72.735

Response from X-Treme Temp Heating & Cooling, LLC:

Thank you so much for this great 5-star review.


Map of Northford, CT 06472

Excellent service




Review of X-Treme Temp Heating & Cooling, LLC

X-treme was great they text me when the tech was on his way along with his name. Andrew was very professional and knowledgeable.we needed a new blower motor and he had the part on the truck!Highly Recommend!

NorthfordCT06472 41.3925-72.8125

Map of Northford, CT 06472

Excellent service and great communication!




Review of X-Treme Temp Heating & Cooling, LLC

NorthfordCT06472 41.42-72.75

Andrew H.

Andrew H.

Brushed and vacuumed flue pipe and heat exchanger Replaced oil filter, nozzle, and strainer Checked all electrical connections and safeties Performed combustion and smoke tests 7.5%o2 35ppm co 0 smoke Recommend having a chimney person come out as soon as possible. The chimney is starting to get blocked with soot and there are leaves and brick in the chimney. Greg’s chimney 203 630 1976

Near Skylark Dr, Northford, CT 06472
Andrew H.

Andrew H.

Brushed and vacuumed flue pipe and heat exchanger Replaced oil filter, nozzle, and strainer Checked all electrical connections and safeties Performed combustion and smoke tests 8.2%o2 23 ppm co 0 smoke While performing the maintenance we found 2 hi-vents that had leaked in the past and have some minor corrosion on them. Recommend replacing the hi-vents at some point in the future. Recommend having a chimney person come out and inspect the chimney. We found a couple leaves in the flue pipe. Greg’s chimney 203 630 1976

Near Skylark Dr, Northford, CT 06472
Larry H.

Larry H.

Performed a heating pm on an oil furnace Brushed and vacuumed. Replaced the oil filter, nozzle and strainer. Replaced the air filter with customer supplied. Started and checked the safeties. Performed a combustion test. 4.6% o2, 2 ppm, 87.7% efficient System is operating properly.

Near Foote Hill Rd, Northford, CT 06472
Larry H.

Larry H.

Performed a heating pm on an oil furnace. Brushed and vacuumed. Replaced the oil filter, nozzle and strainer. Started and checked the safeties. Performed a combustion test. System is operating properly.

Near Reeds Gap Rd, Northford, CT 06472
Larry H.

Larry H.

Performed a heating pm on an oil boiler. Brushed and vacuumed. Replaced the oil filter, nozzle and strainer. Started and checked the safeties. Performed a combustion test. 4.2% o2, 5 ppm, 83.3% efficient System is operating properly.

Near Old Post Rd, Northford, CT 06472
Andrew H.

Andrew H.

Performed oil heating pm on water heater and boiler Brushed and vacuumed flue pipes and heat exchangers Replaced oil filter, nozzles, and strainers Checked all electrical connections and safeties Performed combustion and smoke tests Boiler-5.2%o2 40 ppm co 0 smoke Water heater- 6.1%o2 37 ppm co 0 smoke Customer stated they have air in the lines again and would like a quote for an air removal device. Will look into pricing for both an air scoop and spirovent. While installing that we also have to replace the pressure relief. Piping is 1 1/4” before the manifold.

Near White Hollow Rd, Northford, CT 06472
Larry H.

Larry H.

Performed a heating pm on an oil boiler. Brushed and vacuumed. Replaced the oil filter, nozzle and strainer. Started and checked the safeties. Performed a combustion test. System is operating properly. The oil leak at the tank was from the bottom of the oil filter canister. The inside was pitted and staring to leak. Replaced the bottom half of the oil filter canister and checked for leaks. There is rust on top of the extrol tank from a previous leak. Recommend replacing before it starts to leak.

Near Mountain View Terrace, Northford, CT 06472
Andrew H.

Andrew H.

Upon arrival unit was off. checked air filter and evaporator coil. Evaporator coil was clean but the air filter was slightly dirty. Replaced the air filter started and tested unit with both zones on. The indoor unit turned on, but only the condenser fan turned on outside. Upon further investigation, we found the capacitor for the compressor was bad. After getting customer authorization, we replaced the capacitor. Started the unit. Found the pressures were slightly high and condenser coil was dirty. Rinsed off outdoor condenser coil with water. Started and tested the unit and found the pressures dropped after the condenser coil was clean. Unit is now working properly and refrigerant levels are within manufacturer’s specifications. Recommend installing a discharge air temp sensor.

Near Youngs Apple Orchard Rd, Northford, CT 06472
Andrew H.

Andrew H.

Visually inspected indoor evap coil and blower compartment Checked all electrical connections and safeties Checked volts and amps Visually inspected air filter Rinsed condenser coil Blew out drain line and poured water to ensure properly draining Tested condensate pump Checked refrigerant levels Checked capacitor Took temps While performing the maintenance we found the capacitor was very weak. It was rated at 45b5 and was reading 42/2. After getting customer authorization we replaced the capacitor. When starting and testing the unit we found the system was low on refrigerant. After getting customer authorization we added 1 lb R410A to the system bringing the subcooling from 1.5 up to 12.8 which is within manufacturer’s specifications. Recommend reassessing the refrigerant levels next year. While performing we found the installer used silver solder instead of braze at the refrigerant pipe connections. It is possible the refrigerant is leaking from there since silver solder is not

Near Foote Hill Rd, Northford, CT 06472
Andrew H.

Andrew H.

Visually inspected indoor evap coil and blower compartment Checked all electrical connections and safeties Checked volts and amps Visually inspected air filter Rinsed condenser coil Blew out drain line and poured water to ensure properly draining Checked refrigerant levels Checked capacitor Took temps

Near Humming Bird Dr, Northford, CT 06472
Andrew H.

Andrew H.

Upon arrival unit was on but only the indoor unit was running. Upon investigation found the condenser was off on low pressure. Inspected the wiring and did not find any breaks. Due to the chipmunk nest in the past it is possible the copper is now porous because of the pee. Added 6lbs 8 oz R410A and UV dye to the system. When leaving pressures were 127/328 with 15.8 subcooling. Unit is working properly. Need to return to find the UV dye

Near Reeds Gap Rd, Northford, CT 06472
Andrew H.

Andrew H.

Visually inspected indoor evap coil and blower compartment Checked all electrical connections and safeties Checked volts and amps Visually inspected and replaced air filter Rinsed condenser coil Blew out drain line and poured water to ensure properly draining Tested condensate pump Checked refrigerant levels Checked capacitor Took temps Brushed and vacuumed flue pipe and heat exchanger Replaced oil filter, nozzle, and strainer Checked all electrical connections and safeties Performed combustion and smoke tests 5.3%o2 45ppm co 0 smoke

Near Maria Todd Rd, Northford, CT 06472
Andrew H.

Andrew H.

Visually inspected indoor evap coil and blower compartment Checked all electrical connections and safeties Checked volts and amps Visually inspected air filter Rinsed condenser coil Blew out drain line and poured water to ensure properly draining Tested condensate pump Checked refrigerant levels Checked capacitor Took temps

Near Dayton Hill Rd, Northford, CT 06472
Larry H.

Larry H.

Had the customer turn the thermostat up. The circulator turned on and the temperature dropped to 120* and the burner did not turn on. Checked for power in the aquastat. “B1” for the burner had 120v but the burner was not running. Went to remove the primary and the burner started. The relay inside the primary control is intermittently pulling in. The primary control needs to be replaced. Replaced and tested. The system is operating properly.

Near Forest Rd, Northford, CT 06472
Larry H.

Larry H.

Performed a heating pm on an oil boiler. Brushed and vacuumed. Replaced the oil filter, nozzle and strainer. Replaced the air filters with customer supplied. Started and checked the safeties. Performed a combustion test. System is operating properly.

Near Foote Hill Rd, Northford, CT 06472
Larry H.

Larry H.

Performed a heating pm on an oil furnace Brushed and vacuumed. Replaced the oil filter, nozzle and strainer. Checked air filters. Customer just replaced them. Started and checked the safeties. Performed a combustion test. System is operating properly.

Near Reeds Gap Rd, Northford, CT 06472
Andrew H.

Andrew H.

Upon arrival we found that a circulator pump was making a chirping noise due to having low/no water to push because of a pocket of air. Added some water to the system and it knocked the air pocket loose letting the circulator push water. Hooked up the hose and bled all 3 zones of air until there was cold water coming back. Started and tested system on all 3 zones. Had hot water coming back on all 3 zones. Unit is working properly. Pressure when leaving was at 20

Near White Hollow Rd, Northford, CT 06472
Larry H.

Larry H.

Performed a heating pm on an oil boiler. Brushed and vacuumed. Replaced the oil filter, nozzle and strainer. Started and checked the safeties. Performed a combustion test. System is operating properly. The repairs that were noted last year have not been repaired.

Near Old Post Rd, Northford, CT 06472
Andrew H.

Andrew H.

Brushed and vacuumed flue pipes and heat exchangers Replaced oil filter, nozzles, and strainers Checked all electrical connections and safeties Performed combustion and smoke tests Water heater- 4.1%o2 9ppm co 0 smoke Furnace-3.5%o2 0 ppm co 0 smoke

Near Humming Bird Dr, Northford, CT 06472
Larry H.

Larry H.

Performed a heating pm on an oil boiler. Brushed and vacuumed. Replaced the oil filter, nozzle and strainer. Started and checked the safeties. Performed a combustion test. System is operating properly. There is rust on top of the extrol tank. In the future the tank will need to be replaced before it starts to leak.

Near Mountain View Terrace, Northford, CT 06472
Larry H.

Larry H.

Performed a heating pm on an oil boiler. Brushed and vacuumed. Replaced the oil filter, nozzle and strainer. Started and checked the safeties. Performed a combustion test. 5.5% O2, 3 ppm CO, 84.2% efficient System is operating properly.

Near Old Post Rd, Northford, CT 06472
Larry H.

Larry H.

Performed A/C pm on system. Blew out drain line. Checked air filter. Rinsed condenser coil. Checked electrical connections, pressures, and temps. System is operating properly.

Near Humming Bird Dr, Northford, CT 06472
Andrew H.

Andrew H.

Visually inspected indoor evap coil and blower compartment Checked all electrical connections and safeties Checked volts and amps Visually inspected air filter Rinsed condenser coil Blew out drain line and poured water to ensure properly draining Tested condensate pump Checked refrigerant levels Checked capacitor Took temps Duct diagnostic 2037341532

Near Humming Bird Dr, Northford, CT 06472
Andrew H.

Andrew H.

Upon arrival replaced media air filter. Found that the water heater drain and the pressure relief were both dripping slowly. Attempted to drain water heater down via the drain and could not due to a sediment blockage internally. After getting customer approval we replaced the drain and drained the water heater. We then replaced the pressure relief valve and flushed the water heater to remove sediment. Filled water heater back up and started the water heater. Unit is working properly.

Near Berncliff Dr, Northford, CT 06472
Andrew H.

Andrew H.

Brushed and vacuumed flu pipes and heat exchangers Replaced oil filter, nozzles, and strainers Checked all electrical connections and safeties Preformed combustion and smoke tests Boiler-4.8%o2 60ppm co 0 smoke Water heater 6.3%o2 37ppm co 0 smoke

Near White Hollow Rd, Northford, CT 06472
Call X-Treme Temp 203-815-6851 or Contact Us
Request An Appointment Today
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Date Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon
Back Next