Heating Cooling Services Cromwell CT

Keep Your Home Comfortable With Quality HVAC Services In Cromwell CT

X-Treme Temp Heating & Cooling is your go-to HVAC service provider in Cromwell, CT! We’re the experts in home comfort year-round, from AC and heating repair to ductwork and water heaters. We’ve got you covered from installation to maintenance so you can have peace of mind about your heating and air conditioning.

Read the reviews below from Cromwell, CT residents to see what your neighbors say about our expertise and customer service. We can’t wait to work with you!

Local Reviews
for Cromwell, CT



Andrew H.

Andrew H.

Brushed and vacuumed flue pipe and heat exchanger Replaced oil filter, nozzle, and strainer Checked all electrical connections and safeties Performed combustion and smoke tests 5.7%o2 30ppm co 0 smoke Replaced 3 6” flue pipe 90’s and 2 sections of flue pipe due to corrosion.

Near Millennium Dr, Cromwell, CT 06416
Brandie-Lynn T.

Brandie-Lynn T.

During the repair of a Rheem Performance Platinum 50-Gallon water heater, I identified a failed heating element and a malfunctioning thermostat. The heating element had corroded, leading to insufficient hot water production. I replaced both the lower heating element and the thermostat with OEM parts. After reassembling, I tested the unit to ensure it was delivering consistent and optimal hot water performance.

Near Lancaster Rd, Cromwell, CT 06416
Andrew H.

Andrew H.

Upon arrival removed old control board. Wired in the new control board and redid some burnt connections. Started and tested the fan operation in the heating mode and just by itself. Unit is working properly.

Near Millennium Dr, Cromwell, CT 06416
Andrew H.

Andrew H.

Upon arrival unit was off. Turned unit on and the burner turned on and then turned off on high limit but the blower motor never turned on. Checked the capacitor and it was good. Checked power coming off of the board onto the fan terminal and had no power. Jumped incoming power over to the fan wire and the fan turned on properly. The control board is not sending power to the fan to turn on even though it should be. Need to return to replace the control board.

Near Millennium Dr, Cromwell, CT 06416
Andrew H.

Andrew H.

Visually inspected indoor evap coil and blower compartment Checked all electrical connections and safeties Checked volts and amps Visually inspected air filter. Rinsed condenser coil Blew out drain line and poured water to ensure properly draining Tested condensate pump Checked refrigerant levels Checked capacitor Took temps After getting customer authorization we replaced the capacitor due to it being under factory specifications

Near Millennium Dr, Cromwell, CT 06416
Jonathan L.

Jonathan L.

Upon arrival found the flue pipe to be paper thin and falling apart. Repair was quoted out at $285. The homeowner approved of the repair for $285. Removed section of old flue and installed new flue pipe in its place. After repairing flu pipe, an oil maintenance was performed. Brushed and vacuumed soot and debris from the heat exchanger. Checked electrical connections and safeties. Performed a combustion test on unit, unit is running at 5.4% O2, 20ppm CO, with zero smoke. 30 dollar discount was added for heating maintenance.

Near Millennium Dr, Cromwell, CT 06416
Andrew H.

Andrew H.

Removed old timer control board and replaced with new one. Started and tested unit. Unit is running at 8.6%o2 20ppm co. Unit is working properly. Need to return to replace mixing valve gaskets. Took pictures and uploaded them to companycam.

Near Shadow Ln, Cromwell, CT 06416
Dyllan  M.

Dyllan M.

Upon arrival the compressor and the suction line was iced up. Because it was so hot out the ice melted quickly. We found the air filter was extremely dirty. Replaced the air filter. It was a 25x16x1. The humidifier that was on the back of the furnace has melted and left a gaping hole in the ductwork. It was disabled and non functional so We removed the humidifier and patched the ductwork. I had to add 2lbs of r22 refrigerant. There was a 18*f delta t. The unit is working properly. The unit is from 2001. Also noticed that the flue pipe for the furnace was paper thin and very brittle. Will need to quote out a price to replace it before heating season.

Near Millennium Dr, Cromwell, CT 06416
Call X-Treme Temp 203-815-6851 or Contact Us
Request An Appointment Today
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Date Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon
Back Next